top of page

Pre-clean 105


                                                 Description
A blend of cleaning and passivating agents,Pre-Clean105 is specially formulated to act as filter between traditional cleaning and passivation.Leftover oils and soils often create problems in passivation bath and effect the quality of passive surface.
ace Pre-Clean105 effectively cleans the leftover oils and soils to create a surface ready for passivation.

Pre-Clean105 has been used over the years by stainless steel instruments/parts industry. 
​Equally good for all grades of stainless steel. 

                                   Application Procedure
Pre-Clean105 should be mixed with clean water (purified water if desired) at a ratio of 1 part of Pre-Clean105 with 2 parts of water by volume to fill the tank used so as to adequately cover all parts to be treated. 

Polypropylene, stainless steel, or equivalents should be used for construction of all tanks and devices used in the Pre-clean bath. Agitation of the solution in the tank is recommended to attain optimum results.

Pre-Clean105 does not effect the base metal.
Flexible batch schedules are possible.
Appearance: Transparent Liquid
Flash point: None

Warm the solution for optimum performance. 60-80Celsius  is typical. Room temperature is often adequate with increased immersion time. Completely immerse the parts to be passivated in the solution for a period sufficient to remove all free iron and contaminants from the surface.
 
Dipping time 20-45 minutes, depending on temperature, grade of stainless steel, hardness and the condition of the surface of the parts. 

                                       Notes on Use
May be corrosive to some metal,masonary,irritant to skin.Harmful for eyes and if swallowed.Avoid spilling.
 
Do not breath vapours,mist or fumes.Work in a good ventilated area or wear respiratory protection.
Flush with water in case of prolonged skin contact or spill.
Wear eye protection.
 
Every product has different machining and structure therefore please check the compatibility of the chemical before industrial application. 
 
                                      
                                                

 